Feature
- Bit rates up to 1 Mbit/s
- Compliant with CAN specifications 2.0A and 2.0B
- two independent CAN communication ports
- CAN Port galvanic isolation: 3000V DC-DC Power isolation, 2500V Signal isolation
Overview
The CANBridge is used for the galvanic isolation of two segments of a CAN network and offers a very high galvanic isolation of 2.5 kV, and for creating star or tree topologies, and for extending the transmission distance, and for Increasing the number of nodes. Via the integrated CAN bridge two CAN networks with different bit rates can easily interconnected.
CAN Communication
CAN Ports: 2
CAN Specification: Compliant with CAN specifications 2.0A (11-bit ID) and 2.0B (29-bit ID)
Connector Type: 3-pin removable screw terminal
Signal Support: CAN_H, CAN_L, GND
Isolation Protection: 3000V DC-DC Power isolation, 2500V Signal isolation
LED Indicators: Power, CAN1, CAN2
Termination Resistor: Dip switch selector for 120 Ω terminal resistor.
Configuration
Configuration Software: CANBridgeConfigTools for windows.
Physical Characteristics
Dimensions: 103 x 72 x 20 mm
Environmental Limits
Operating Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Power Requirements
Input Voltage: 9 to 32 VDC power inputs
Connector Type: 2-pin removable screw terminal
Power Consumption: 150 mA @ 12 V
Housing
DIN-Rail mounting (standard), Wall mounting (optional)